Steel Soldiers now has a few new forums, read more about it at: New Munitions Forums!
Microsoft MSN, Live, Hotmail, Outlook email users may not be receiving emails. We are working to resolve this issue. Please add support@steelsoldiers.com to your trusted contacts.
Don't mean to hijack this thread. But I've only shared about it on my facebook page. I might spin something up here in the mess hall if anyone is interested. Cliff notes: 8.8 big block that will make 1K hp+ on pump gas with low boost under 6K rpm. I'm even going to have AC and all the...
Yes, that'd be the primary use of it for me. Yes, I could try to run cords off and load other things exclusively to the 3rd phase leg, which I've tried to do as well. But in my mind, I'd rather employ two transformers in open delta to simply tie that 3rd leg in and get the single phase output...
No, that wouldn't address the concern of balance. And rectifiers would produce a unclean output.
I'm thinking two buck transformers wired in the way the power company would wire a 3ph run into a single phase open delta setup with two transformers.
I'm thinking something more agnostic that wouldn't require any changes to the gen head configuration or ECU. Simply tapping out of the leads from one or more of the breakers to feed into a pair of buck transformers in open delta that then you'd establish another breaker box setup.
You can ask, but I'd be certain if they're building the HVAC side of it, they're only interested in the 3ph power from the genset. I'm trying to devise a way to have a easily "switched" output from 3ph to single but still retain the HVAC/3ph if/when needed.
The only thing I can add is the fact a gen 5 454 was weak sauce from the factory. 230hp new and 385ft-lbs. The 6.5 in question is only 160-170/290-300ft-lbs NA. But if you added a 6.5 turbo setup to it, you'd get closer to the 454's factory power at 190-200hp/380-400ft-lbs. And you'd be able...
I realize many of the military gensets can be reconfigured at the head to single phase. I've got a DRASH trailer, but as I understand, it will not easily be converted to single phase without causing some grief due to the control side of it.
What I wondered is if anyone here has employed two...
Welcome to the MV of the YEAR poll sponsored by Consolidated Press. If you need decals, magnets, stencils, or anything printing related, please give them a call!
Now, onto the vote! Please vote for MV of the YEAR! Feel free to campaign in...
We have our winners.
First place is:
@jlr113
Second place:
@Capt Pat
Third place is:
@sf1954
You will have a group email sent directly from me to Dave to coordinate all the details. Thank you everyone!
Going live here shortly to do the drawing for the prizes for the DOT 5 giveaway. I have locked the thread and currently compiling the list of extra entries.
Welcome to the MV of the month poll sponsored by Consolidated Press. If you need decals, magnets, stencils, or anything printing related, please give them a call!
Now, onto the vote! Please vote for MV of the month! Feel free to campaign...
This site uses cookies to help personalise content, tailor your experience and to keep you logged in if you register.
By continuing to use this site, you are consenting to our use of cookies.